Model : FTB9050-80-150
Current : 150A
Voltage : 80V
Power : 5kW
Regenerative Load Function:
Reduces electricity costs and heat generation by feeding back energy to the factory intranet with 95% conversion efficiency
Wide Operating Region:
Combines power supply and electronic load with energy recovery capability for seamless switching between sourcing and sinking
High Power Density:
18 kW/3U with accurate output, fast response, and low ripple noise
User-Programmable Sequence Function:
Simulates power interruptions, voltage drops, and other changes with 10 sequence files and 100 steps each
Four Basic Load Modes:
Constant current, constant voltage, constant power, and constant resistance for various testing needs
Ideal for:
Testing motors, battery packs, BMS, energy storage systems, and other applications
Feature
Output voltage: 80 V up to 2250 V;
Output current: up to ±4500 A;
Output power: standalone 5 kW up to ±180 kW, parallel up to ±1800 kW;
0.02%+0.02%F.S. and 0.1%+0.1%F.S. accuracy for voltage and current measurement respectively;
Power factor 0.99, efficiency > 93%;
Regenerative load function, regenerative efficiency up to 95%;
Bi-directional power transfer, seamless switch between sourcing and sinking;
Autotomatic line loss compensation;
CV, CC, CP, CR function;
CV / CC priority start (prevents voltage or current overshoot with output ON);
Adjustable voltage/current slew rate;
Voltage ramp function; charge/discharge function;
User programmable sequence function;
Battery simulator function (optional);
Support photovoltaic battery array simulation function (optional);
OVP, OCP, OPP, OTP, LVP etc. protection functions;
High-voltage isolated digital, analog, monitoring and control interfaces;
Standard LAN, USB (serial), optional RS485, GPIB or CAN ports;
Support SCPI, MODBUS, CAN-OPEN (optional) protocol;
18 kW / 3U high power density, standard 19-inch chassis design.